FLIR GF304 w/14.5° Lens, 320 x 240 Resolution, also available 24° Lens

The FLIR GF304 is an infrared camera for optical gas imaging (OGI) that visualizes and pinpoints leaks of refrigerant gases, without the need to shut down the operation. This portable camera also greatly improves operator safety, by detecting gases at a safe distance, and helps to protect the environment by tracing leaks of environmentally harmful gases.
Refrigerant gases are found in, for example, the food, chemical/petrochemical, and automotive industries, as well as in air-conditioning systems.
Detects the following refrigerant gases: R404A, R407C, R410A, R134A, R417A, R422A, R507A, R143A, R125, R245fa.

Key Features:

  • Improved efficiency: The FLIR GF304 reduces revenue loss by pinpointing even small gas leaks quickly and efficiently, and from a distance. It also reduces the inspection time by being able to scan a broad area rapidly without the need to interrupt the industrial process. The wireless connectivity of the camera allows you to connect to smart phones or tablets for the wireless transfer of images or the remote control of the camera. The FLIR GF304 can also be used for temperature measurement, which makes it even more useful for predictive maintenance.
  • Increased worker safety: The leak detection of gases can be performed in non-contact mode, and from a safe distance. This reduces the risk of the user being exposed to invisible and potentially harmful or explosive chemicals. With a FLIR GF304 gas-imaging camera it is easy to scan areas of interest that are difficult to reach with conventional methods. The camera is ergonomically designed, with a bright LCD and a tiltable viewfinder, which facilitates its use over a full working day.
  • Protecting the environment: Several refrigerant gases have a high global warming potential and are usually governed by regulations. Even small leaks can be detected and documented using the FLIR GF304 camera.
SKU: 59601-0101 Categories: , , , ,

Description

Technical Specifications:

Imaging and optical data
IR resolution 320 × 240 pixels
Thermal sensitivity/NETD <15 mK @ +30°C (+86°F)
Gas sensitivity (NECL) SF6: < 0.3 ppm x m(ΔT = 10°C, Distance = 1 m)
Field of view (FOV) 14.5° × 10.8°
Minimum focus distance 0.5 m (1.64 ft.)
Focal length 38 mm (1.49 in.)
Lens identification Automatic
F-number 1.5
Focus Automatic (one touch) or manual (electric or on the lens)
Zoom 1–8× continuous, digital zoom
Digital image enhancement Noise reduction filter, high sensitivity mode (HSM)
Detector data
Detector type Focal plane array (FPA), cooled QWIP
Spectral range 8.0–8.6 µm
Detector pitch 30 µm
Sensor cooling Stirling Microcooler (FLIR MC-3)
Detects following gases R404A, R407C, R410A, R417A, R422A, R507A, R143A, R125, R134A, R245fa
Electronics and data rate
Full frame rate 60 Hz
Image presentation
Display Built-in widescreen, 4.3 in. LCD, 800 × 480 pixels
Viewfinder Built-in, tiltable OLED, 800 × 480 pixels
Automatic image adjustment Continuous/manual; linear or histogram based
Manual image adjustment Level/span
Image presentation modes
Image modes IR image, visual image, high sensitivity mode (HSM)
Measurement
Temperature range –20°C to +250°C (–4°F to +482°F)
Accuracy ±1°C (±1.8°F) for temperature range (0°C, to +100°C, +32°F to +212°F) or ±2% of reading for temperature range (>+100°C, >+212°F)
Measurement analysis
Spotmeter 10
Area 5 boxes with max./min./average
Profile 1 live line (horizontal or vertical)
Difference temperature Delta temperature between measurement functions or reference temperature
Reference temperature Manually set or captured from any measurement function
Emissivity correction Variable from 0.01 to 1.0 or selected from editable materials list
Reflected apparent temperature correction Automatic, based on input of reflected temperature
Measurement corrections Reflected temperature, distance, atmospheric transmission, humidity, external optics